Our Products

 
Dynamometers & Controllers
 
The Eddy Current Dynamometers are available from 70hp to 700hp models and speed ranging upto 10000 rpm. These can be used to cover a wide range of testing from R&D and production testing of petrol and diesel engines to electrical motor testing to gear box test rigs.
Arrow
Fast loading and unloading
Arrow
Bi-directional operation
Arrow
Low inertia rotor
Arrow
Cooling water pressure and body temperature monitoring
Arrow
Digital speed measurement accuracy: ±1 rpm
Arrow
Torque measurement accuracy: < ±0.25% F.S.
Product
Models:
Arrow
70 ECA (Max. Torque: 80 Nm, Max. Power: 52 KW)
Arrow
100 ECA (Max. Torque: 175 Nm, Max. Power: 73.5 KW)
Arrow
200 ECA (Max. Torque: 500 Nm, Max. Power: 148 KW)
Arrow
350 ECA (Max. Torque: 1200 Nm, Max. Power: 267 KW)
Arrow
700 ECA (Max. Torque: 2000 Nm, Max. Power: 515 KW)
 
 
The Digital Dyno Throttle Controller provides precise control on and operation for an Eddy Current dynamometer.
Arrow
Precise operation through excellent torque and speed control stability
Products
 
Arrow
Bumpless transfer of modes with Digital PID control
Arrow
LCD display for indication of demand values, actual values of position, torque, speed and power, operating menus, parameter settings, and messages.
Arrow
Dyno & Throttle demand value setting via 2 incremental encoders
Arrow
Devoted push button switches for mode and other selections
Arrow
Interface to throttle actuator position control
Arrow
Accuracy for speed: ±1 rpm
Arrow
Accuracy for torque: better than ±0.25% F.S. including Dynamometer
  Model: EDTC-8000V2
Model HDTC-8000V2 available for operating Hydraulic Dynamometer.
 
 
 
The analog Eddy-current Dynamometer Controller is a control and indication system for operating a Eddy Current Dynamometer.
Arrow
Local and remote control facility with PID control operation
Arrow
Push button switches for mode selection with Mode change interlock for safety
Arrow
Digital indication of speed and torque on front panel
  Models: EDC-95
 
 
The system is used to control the position of the Throttle Actuator particularly applicable for a complete engine or dynamometer test facility with remote control.
Arrow
Fast response with high transient torque capacity
Product
Arrow
Manual and automatic adjustment of zero and span position (from 0-15mm upto 0-100mm)
Arrow
4 different force limits in the steps of 75N (Max. 300N), in both, Push and Pull directions
Arrow
Fine resolution for precision control: better than ±0.1mm.
Arrow
Position accuracy of 0.05% F.S.
Arrow
External interfaces
  Models: TAC-9000 (Digital Type).
Other Models: TAC-92P (Analog Type Position Control)
 

Product Categories